4-33
4
Daily Maintenance
Replacing exhaust blower
Using exhaust blower, the heat generated at the time of making drawings is exhausted.
The ink mist sucked in at such time will be hardened and disturb the normal operation of the exhaust
blower.
Replace the exhaust blower in the following situations:
When the exhaust blower does not function normally
“ERROR706 UV1 overheat” will be displayed frequently.
1
Put off the UV lamp and turn OFF the power.
2
Remove the front right cover and the front left cover.
3
Remove the connector of the exhaust
blower connecting cable.
4
Pull out the exhaust blower Assy
upward.
• Pull out after removing the finger screws attached
to the top of the exhaust blower Assy.
Tools required for
replacement
• Phillips screwdriver
Connector
Exhaust blower
Assy
Pull out
Comments to this Manuals