Basic Operations
Test drawing
Make test drawing to check whether there is nozzle clogging or other drawing failures (such as wearing or
missing).
Execution of test drawing
1
Press the key in the local mode.
2
Press or key to select “NOZZLE CHK”.
Select “HARDEN CHK” to confirm that UV ink has not been cured.
( P.4-42)
3
Press the key.
Test drawing is started.
4
Test drawing ends
Returned to the local mode.
Execute operation of PXX, when evacuation of the Y-bar is required.
5
Check result of drawing
When the result is normal, finish the operation.
When the result is abnormal, execute head cleaning. ( P.2-10)
Printing is disabled when the following messages are displayed. It is enabled when the
message has disappeared.
“WATER NOT READY” The temperature of water in the hot water device has not
reached the predetermined value.
“UV NOT READY” UV irradiation device is not ready.
Check before starting
test drawing
Is media set ? ( P.2-5) Is origin point set ?
Is head gap value registered ? ( P.3-7)
Normal pattern
Abnormal patterns
Nozzle drop out Nozzle missing Deflection
TEST DRAW
NOZ Z L E CHK <ENT >
TEST
** TEST DRAW **
ENTER
Many lines are missing. The lines are missing as if
the teeth are lost.
The distance between the
lines is narrowing or
double lines are formed.