3-12
Setting the light intensity of the UV lamp
The light intensity of the UV lamp may be set in 3 stages.
This setting is made when the media vulnerable to the heat is used or when the test drawing is made in
which the lighting of the UV lamps is not desired.
1
Press the key in the local
mode.
2
Select the [SET UP] by pressing
the or key.
v
3
Press the key.
4
Select the [UV LEVEL] by pressing
the or key.
5
Press the key.
6
Press or keys to select light intensity.
Set values :HIGH , STANDARD , LOW , NONE , NOPRINT
7
Press the key.
8
Press the key twice to finish
HIGH The UV lamp is lit with 100% of its light intensity.
STANDARD The UV lamp is lit with 60% of its light intensity.
LOW The UV lamp is lit with 40% of its light intensity.
NONE The UV lamp is not lit while drawing is being performed.
NOPRINT
The drawing is not performed and only the UV lamp is lit. Use when drawing is performed
without the UV lamp is lit etc., and when you wish to make it cure afterward. (Normally,
this setting will not be made.
The light intensity of the UV lamp may be set on the RIP side, when performing the remote
drawing. For details, please refer to the Instruction Manual of your RIP.