1-4
Operation Panel (JF-1631)
The operation panel is used for setting of drawing method and each operation.
Function of Jog Keys
A function of the Jog key is different by the timing to be used.
At drawing origin, area
setting
At function selection At setting selection
Shifts the carriage to the left
Shifts the carriage to the right
Shifts the carriage to back Return to the previous function Select the previous function
Shifts the carriage to front Move to the next function Select the next value
Display
Displaying state of the unit, setting items, errors,
and so on.
VACUUM Lamp ( P.2-5)
Lit when media is set.
BLOW Lamp ( P.2-12)
Lit when media is removed from the table.
Key ( P.2-5)
Switching VACUUM to BLOW, and vice
versa.
VACUUM/BLOW
key
For switching a setting of VACUUM/BLOW at rear side of the table.
REAR
key
For switching a setting of VACUUM/BLOW at front side of the table.
FRONT
POWER Lamp
Lit when the power is ON.
Key
Press to start the test drawing.
( P.2-9)
TEST
Key
Press to start the head cleaning.
( P.2-10)
CLEANING
Key
Press to erase received data.
( P.3-9)
DATACLEAR
JOG key
Used for moving of the Y-bar and for each setting.
key
Press to use each function.
FUNCTION
key
Switching the remote mode and the
local mode, and vice versa.
( P.1-13)
REMOTE
key
Press to finish the setting.
END
key
Press to determine a setting.
ENTER
key
Press to elevate the Y-bar. ( P.3-6)
UP
key
Press to down the Y-bar. ( P.3-6)
DOWN
Page view 21