– 5.19 –
5-3-7. HEAD ID
[Function]
The setting value is issued in the maintenance list at the time of maintenance release.
Enter the ID numbers of heads 1 to 3. The input values are stored under system parameters
No. 1 to 3.
The ID numbers are sealed and stuck on each print head.
[Operation]
1) Select the ADJUSTMENT, and then press the
ENTER
key.
2) Select the “HEAD ID”, and then press the
ENTER
key.
3) Press the
ENTER
key again, and then the
ID number can be entered.
Use the
and keys to move left or right.
Use the
and keys to enter the number.
Press the
ENTER
key to finalize the number.
When the
key is pressed, the value
returns to what it was before the change.
4) After the ID numbers of heads 1 to 3 have been
entered, press the key.
The values that were input are stored under system
parameters, and this operation ends.
Incorrect entry in step 3) results in an error when the
ENTER
key is pressed.
Since the entry remains intact, modify the number and then normally terminate
the entry.