– 5.9 –
If “FINE” has been selected )
”FINE” is used to check, or perform fine adjustment of, the X PRINT, Y SINGLE, Y REPEAT,
and Y BI-D correction values. Accordingly, perform the “FINE” after the X PRINT, Y
SINGLE, Y REPEAT, and Y BI-D corrections have been performed.
Adjust the shot so that the pattern (Y SINGLE, Y REPEAT) for dot position correction
[FINE] totally be as uniform as possible.
[ Example of Y SINGLE, Y REPEAT, and Y BI-D drawing ]
Y BI-DIRECTIONAL / FINE, the above pattern is plotted only in black.
K+C+Lm C+Lm K+Lm K+C Head3 Head2 Head1
Head2 Head1
When the dot position viewed from the scope is as
shown above, enter a positive value as the correction
value for HEAD1 and HEAD2.
4 scan
3 scan
2 scan