– 3.25 –
3-4-10. Banding occur
Problems Banding (wind repples) occur at each scan.
Causes 1) The head is too high. ( The gap is too large.)
Checking procedures 1) Lower the head and then make plotting.
Remedies 1) If Banding is solved, the accuracy of the device is assumed to be normal.
Change the plot mode to [STANDARD] or [FINE]. With 360 x 360dpi,
change the 2pass mode to the 4pass mode; with 360 x 540dpi, change the
3pass mode to the 6pass mode.
3-4-11. Vertical stripes
Problems Vertical stripes, light or dark, appear in an entire plotted area.
(Especially, in monochrome or halftone prints)
Causes 1) Heat from the heater has extended the media and caused blisters.
Checking procedures 1) Check the media on the platen visually for no blisters.
Remedies 1) Set the takeup strength to Medium or High.
2. Set the heater temperature high within the allowable range.
3. Select [QUALITY : FINE] other plotting mode for the standard speed
(no double speed).