MIMAKI JV3-160S Setup Guide Page 59

  • Download
  • Add to my manuals
  • Print
  • Page
    / 170
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 58
– 3.21 –
3-4-6. Stripes are always drawn at the time of scanning
Problems Black or white stripes are always drawn at the time of scanning.
Causes 1) The value of [MEDIA COMP.] is not correct.
When the media is changed, perform SETUP and [MEDIA COMP.]
to set values which suit the media.
2) A medium that is heavier than the specification is placed. (For the case
where black stripes appear)
3) Thicker media is used. However, the setting values for light-weight
medium remain.
4) The heater temperature setting is not appropriate.
Checking procedures 1) Execute SETUP - [MEDIA COMP.] to check that the value of [MEDIA
COMP.] is correct.
2) Medium weight measurement (medium of which weight is 25 kg or less
is recommended)
3) Check whether or not the distance compensation matches the medium
used.
4) Check that the set heater temperature is appropriate for the media.
Remedies 1) Same as Checking procedure 1).
Note that it may be necessary to specify a media correction value for
same host system. (See the table below)
2) Use a medium of which weight is 25 kg or less.
3) Set the correction value.
4) Set the heaters (pre-heater and print-heater) to appropriate values.
Priority setting Media correction value used
Panel Media correction value set by the user at the time of media correction.
Host Correction value specified by command.
Page view 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 169 170

Comments to this Manuals

No comments