4-2-8. Replacement of the cap
[Parts to be used]
Cap assy. (M004858)
[Adjusting procedure]
1) Turn off the power of the device.
2) Move the head on the platen, remove the station cover F.
3) Remove the joint parts of S cap assy. and S pump assy.
4) Remove the cap assy. and replace it.
Suction side connection joint